Fire Doors in Flats: UK Regulations in Simple Terms

24.11.2026
7 min read
Fire Doors in Flats: UK Regulations in Simple Terms

There’s a lot of legislation surrounding fire doors in flats, particularly after the tragedy at Grenfell.

If you’re in charge of a single flat, a house split into flats or a whole apartment block, you need to be clear on if and where you need fire doors — and the type of flat fire door you need to install.

Here, we provide simple guidance on the UK’s fire door regulations for flats. So you can better understand your responsibilities and keep people safe.

Where are fire doors in flats required?

According to UK fire safety regulations, fire doors are required in several places in a block of flats or a house of multiple occupancy (HMO).

Regulations on external fire doors for flats

Every entrance door to an individual flat that opens onto a shared area — a communal corridor, landing or stairwell — has to be a fire door with an appropriate fire and smoke rating (usually FD30S or FD60S).

These fire-rated flat entrance doors — typically available in timber, composite and glazed options — help to protect shared escape routes. So even if there’s a fire in one flat, residents can still exit the building safely.

Regulations on communal corridors and stairwells

Shared escape routes have to be protected in other ways.

Any other areas (not just flats) opening onto a communal escape corridor or stairway should be fitted with fire-rated doors.

Where you have two or more exits on a single storey, you should also divide the corridor between them with a fire-rated door.

That way, if a fire breaks out at one end of the corridor, at least one exit stays clear of flames and smoke, allowing people to escape.

Regulations on internal fire doors in flats

Ground floor flats don’t usually require internal fire doors, as long as every room has a means of escape — typically a window.

Flats that are 4.5 metres or more above ground level must have internal fire doors between any habitable room and a corridor or stairway. Again, this keeps corridors and stairways clear from flames and smoke, so there’s always an escape route available.

What specification of fire door is required?

For new buildings, or when ensuring adequate fire protection in an older building, you need to conduct a fire risk assessment.

This will indicate where fire doors are needed — and what their specification should be.

If you don’t have a fire risk assessment, you can book a fire safety survey. This will tell you how UK fire door regulations apply to your building.

For most flats, the minimum requirement is an FD30S fire door. This type of door provides 30 minutes of fire resistance and smoke control.

In taller or higher-risk buildings, FD60S doors may be recommended. These doors provide 60 minutes of fire resistance and smoke control, and they give residents more time to escape.

Whichever rating applies, the fire door must meet the following specifications:

  • Independently tested and certified. The door must be accredited by a third-party organisation to BS 476-22 or EN 1634-1 standards.
  • Bidirectionally tested. The door should have been tested to ensure both sides of the door leaf meet the same rating.
  • Complete doorset compliance. The door leaf, frame, hinges, locks, seals, handles, glazing, letterboxes and any other hardware must all meet the required fire door rating.
  • Intumescent and smoke seals. These must be correctly fitted and intact.
  • Self-closing device. The door must close and latch fully every time.

What flat fire door checks are required?

According to UK fire safety regulations, a responsible person has to carry out regular fire door checks in blocks of flats and HMOs.

This person has to:

  • Make sure that all fire doors, including flat entrance doors, provide adequate protection.
  • Provide all residents with information on fire doors, including the need to keep them closed and to contact the landlord if any part of the doorset needs to be repaired or replaced.

In buildings with storeys over 11 metres in height, there are extra responsibilities:

  • Quarterly checks of all fire doors in common areas (including self-closing devices).
  • Annual checks of all flat entrance doors (including self-closing devices).

How do you know if your doors meet flat fire door regulations?

Compliant fire doors in flats should:

  • Have a certification label. This label can be found on the top edge of the door leaf. It will tell you the door’s fire rating and the certifying organisation.
  • Close fully. The door should close and latch fully, without being manually pushed or forced. It shouldn’t be propped open or have the self-closer disabled.
  • Show no visible signs of damage. A damaged fire door may fail to hold back flames and smoke for the advertised time period.
  • Be fitted with appropriate hardware. Every component of the fire doorset has to meet the advertised fire rating. Unauthorised replacements or modifications can affect fire protection and compliance.
  • Have been fitted by a professional. Only a trained and certified fire door installer can ensure that your fire doors are fitted correctly and, therefore, meet UK fire safety regulations.

Where can you read flat fire door regulations in full?

You can read more about fire regulations for flats in the UK here:

Meet regulations for fire doors in flats with FDS

At FDS, we work with landlords, letting agents, housing associations and building contractors across the UK, helping them meet flat fire door regulations.

We supply, manufacture and install certified flat fire doors. We also carry out fire safety surveys and offer maintenance programmes to keep your doors compliant long after installation.

If you’re unsure whether your flat fire doors meet current regulations — or you want to know how much a flat fire door will cost — get in touch.

We’ll give you knowledgeable, straightforward advice on what you need to do to protect people and property, and ensure compliance.

Get in touch to book a fire safety survey or get a fire door quote.

FAQs

Do all flats need fire doors?

Every flat entrance door that opens onto a communal area or corridor must be a fire door. Internal fire doors within individual flats depend on the layout and height of the property. A fire safety survey will confirm what’s required in your building.

What are the flat fire regulations for flat entrance doors?

Flat entrance doors must be FD30S rated at a minimum. These doors provide 30 minutes of fire and smoke resistance. They must be self-closing, correctly installed in a fire-rated frame and maintained in good working order.

How often do flat fire doors need to be inspected?

In buildings with storeys over 11 metres, communal fire doors must be checked quarterly and flat entrance doors annually. In shorter buildings, the responsible person must ensure that fire doors are kept in good working order.

Who is responsible for fire doors and fire safety in flats?

The designated responsible person. This is usually the landlord, managing agent or freeholder. However, residents can do their bit by reporting damage to the fire door and its hardware promptly, and by keeping fire doors shut at all times.

How can you tell if a flat entrance door is fire-rated?

Check for a certification label on the top edge of the door. This should confirm the fire rating and the certifying body. If there’s no label, the door’s certification cannot be verified. It may be a notional fire door but it should be treated as non-compliant until it’s been assessed by a professional.

What happens if flat fire doors don’t comply with regulations?

Doors that don’t comply with UK fire regulations for flats put residents at risk — and expose the responsible person to legal liability. That’s because non-compliant fire doors won’t provide the right level of protection in the event of a fire.

Explore More

Vision panels for fire doors: benefits and ratings
Vision panels for fire doors: benefits and ratings
Vision panels in fire doors are a small addition that makes a big difference — to safety, to light and to how people move around your building. In this post,...
Fire exit doors: regulations for UK businesses
Fire exit doors: regulations for UK businesses
When it comes to workplace safety, fire exit doors are essential. But what exactly are they? What does UK law say about them? And how do you make sure yours are...
Composite fire doors: everything you need to know
Composite fire doors: everything you need to know
Looking for a residential fire door for a flat entrance, an HMO (house in multiple occupation) or any other domestic or commercial application? Composite fire doors...
Bespoke fire doors: benefits, use cases and ordering process
Bespoke fire doors: benefits, use cases and ordering process
Fire doors are an important part of passive fire protection systems. They slow the spread of flames, heat and smoke. They protect escape routes, buy people valuable...
Fire door ratings in the UK explained: FD30, FD60, FD120 and more
Fire door ratings in the UK explained: FD30, FD60, FD120 and more
In a fire, every second counts. And fire-resistant doors give you valuable minutes to evacuate the building and protect your premises while you’re waiting for the...
What is fire compartmentation? And where is it required?
What is fire compartmentation? And where is it required?
If you’re responsible for fire safety in a building, you’ve probably come across the term fire compartmentation. But what does it actually mean? And what fire compartmentation...
Are you looking for reliable & fire rated products in the UK?

We offer fire door installations, a custom-designed fire-rated systems, or fire doors made to size. We will tailor our service to your needs.